2010-9-6 1:54:59
Keywords:
  Hot Products
  AMR system
  DTSF54 tri-phase 4-wire multi-tariff electronic energy meter
  DDSY54 single phase prepayment electronic energy meter
  DTS54 tri-phase 4-wire active electronic energy meter
  DTS54 tri-phase 4-wire AC active electronic energy meter( with RS485 interface)
  DDSF54 single phase multi-tariff electronic energy meter(Fujian version)
  DDSF54 single phase multi-tariff electronic energy meter(Jiangsu version)
  DDS54 single phase electronic energy meter
  DDSF54 single phase multi-tariff electronic energy meter(shanghai version)
  DDS54-J single phase electronic energy meter
DTS54 tri-phase 4-wire AC active electronic energy meter( with RS485 interface)
  (View:2746)   

 
Descriptions 
 
   DTS54 tri-phase 4-wire AC active electronic energy meter (with RS485) is adopting advanced energy measure IC and digital sample process technical design, the meter is applicable measure energy in AC network. The meter is conformed to GB/T17215-2002<> and DL/T645-1997<>.
 
Characteristic
 
1. The meter is small in size, light weight, high precision, low power consumption characteristic etc.
 
2. The meter has bi-direction measure function.
 
3.The meter is adopting photoelectric coupler output test signal, LBD indicates power consumption.
 
4. The meter has RS485 communication interface.
 
5. LCD display or LED display are optional for the meter.

 Main specifications and technical parameters
 
Specifications
 
Specifications and model
Accuracy
Rated voltage(V)
Basic current(A)
DTS54
1.0
3X220/380
1.5(6);10(40);20(80)
 
 
2. Basic errorLtri-phase balance load
 
Load current
Power factor
 Basic error(%)
0.05Ib
1.0
±1.5
0.1Ib~Imax
1.0
±1.0
0.1Ib
0.5(lagging)
±1.5
0.8(heading)
±1.5
0.2Ib~Imax
0.5(lagging)
±1.0
0.8(heading)
±1.0
 
3. electric parameters
 
  Power consumption: voltage circuit<10VA or 2W.
                     Current circuit<0.1VA
 
  Start current: 0.4%Ib(grade 1.0), 0.5%Ib(grade 2.0)
 
  Latent start: with logic anti latent start circuit.
 
  Average service life time: ≥10 years
 
Installation and connection
 
1. Figure dimension: length x width x height = 146mm x 252mm x 75mm
 
2.Weight:1.75kg
 
3.Diagram of connections

 
    DTS54 tri-phase 4-wire electronic energy meter 1.5(6)A
external connected transformer connected diagram
 

 
DTS54 tri-phase 4-wire electronic energy meter
direct connected diagram.
 
Transportation and storage
 
6.1 The meter should be avoided to strike violently during transport and open, and transported an stored according to GB/T15464-1995<< apparatus and meter packing general technical requirements>>.
 
6.2. The meter should be stored and kept on shelf with original packing, the placed height should be not more than 5 layers.
 
6.3 The place of stored should be clean, the temperature should be 0~40℃,relative humidity should be not more than 85%, no caustic substance is in the air.
 
 


 
 
Home About us Contact us Feedback Close windows    
Add:No.16 Xihuan Second Road,Jincheng Industrial Park,Jintan,Jiangsu
Tel:0519-82891660 Fax:0519-82891662 Post coding:213200
Technique support:www.cn-site.com 常州仲裁   中华恐龙园